NIST detects problems in firefighter PPE
Researchers conducted fire experiments on self-contained breathing apparatus facepieces in vacant townhouses in the Chicago area. In two scenarios, the lenses exhibited bubbling, loss of visual acuity, deformation and, in one case, a hole, according to a press release from NIST.
Lens failure puts firefighters at risk for toxic gas exposure, respiratory tract burns and asphyxiation, NIST said.
Researchers tested five models of SCBA facepieces, and found damage was tied to temperatures and heat fluxes beyond performance limits for the polycarbonate lens material, according to the study abstract.
Before being sold, SCBAs undergo certification testing that requires passing the National Fire Protection Association’s “heat and flame test,” the press release stated. The test is conducted at high temperatures, but researchers said it does not reflect the heat conditions firefighters might encounter.
Post a comment to this article
Safety+Health welcomes comments that promote respectful dialogue. Please stay on topic. Comments that contain personal attacks, profanity or abusive language – or those aggressively promoting products or services – will be removed. We reserve the right to determine which comments violate our comment policy. (Anonymous comments are welcome; merely skip the “name” field in the comment box. An email address is required but will not be included with your comment.)